Ozone safely alters the molecular structure of offensive micro-organisms, to eliminate smells from plants, pets, cooking, and smoke. It also kills mould, mildew and bacteria.Uvonair is a high output Corona Discharge generator that produces more ozone than any others known at this time. It is adjustable to match the ozone demand load for odor control as well as provide energy conservation in low demand periods The CD generator does not require servicing.The Uvonair CD-1000 ozone generator will treat all odors being exhausted by a 10" (25cm) ventilation system under most circumstances. The CD-1000-1 is intended for a room size of 20,000 cu.ft. (600 m3) while the CD-1000-2 is intended for a room size of 40, 000 cu.ft. (1200 m3). Installs into other size ducts with adapters. Set the adjustable output by monitoring the exhaustable output by monitoring the exhaust air for odors.The Uvonair CD-1200 ozone generator will treat all odors being exhausted by a 12" (30cm) ventilation system under most circumstances. Intended for rooms up to 100,000 cu.ft. (3000 m3). Installs into other size ducts with adapters. Set the adjustable output by monitoring the exhaustable output by monitoring the exhaust air for odors.

More Views

Details

UVONAIR CD Odor Eliminator Models: CD - 800
Ozone by Corona Discharge CD – 1000-1
CD – 1000-2
In-Duct Ozone System CD – 1200
Installation considerations:
Please read all instructions prior to installation.
1. Uvonair CD ozone generators are engineered to treat odors in ventilation ducts as air is being exhausted. Model CD 800 is
for installation into 8” (20 cm) ducts. Both model CD-1000s are for 10” (25 cm) ducts. Model CD-1200 is for 12” (30 cm)
ducts. Duct adapters may be used for installation into other size ducts. Installing the smaller unit into larger ducts may
restrict airflow.
2. Under most circumstances Model CD-800 and CD-1000-1 will treat all odors being exhausted from rooms up to 20,000 cu.
ft. (600 m³). Model CD-1000-2 will treat all odors being exhausted from rooms up to 40,000 cu. ft. (1200 m³).
3. Model CD-1200, with its significantly higher output, will treat all odors being exhausted from rooms up to 100,000 cu. ft.
(3000 m³). For extreme odors, it is better to use the higher output unit.
4. Position the Uvonair generator if possible a minimum of 15 ft. (5 m) from the end of the exhaust duct to ensure adequate
reaction time with odors. We recommend a minimum of 15 ft. (5m) of ductwork.
5. When using a fan, always put the ozonator on the output side of the fan.
Electrical requirements:
Install in accordance to local electrical standards. Provide 110V 60Hz electrical power to the Uvonair CD ozone generator
synchronized with the ventilation fan. As a safety feature, Uvonair CD unit must be working in tandem with the ventilation
exhaust fan. Uvonair CD is equipped with a 6 ft. (2 m) cord with a grounded three-prong plug and a surge protection fuse.
Installation:
1. Attach the two supplied support brackets to the top of the unit using the four screws already set in place.
2. Turn off the ventilation fan and ensure the Uvonair unit is not plugged in.
3. For installation into metal duct:
a) It will be necessary to remove an approximate 11.5” (29 cm) section of duct where the unit is to be installed.
Consult a ventilation professional for the specific length as this may vary depending on the existing duct setup
and its ability to adjust for the insertion of the Uvonair CD generator.
b) Support the weight of the unit with duct-hanging wire from the support bracket to a hook or nail on the joists
above. Make final adjustment after final installation.
c) Insert the unit into the existing ducts up to mounting ridges and make it airtight using duct tape or clamps.
For installation using flex duct as an option:
a) Remove a 36”(91cm) section of duct.
b) Cut two 17”(43cm) pieces of flex 8” (20cm) diameter duct.
c) Attach to each side of the Uvonair generator and then secure to the ductwork making it airtight with duct tape or
clamps
Operations:
Both Uvonair CD models have High and Low output settings so you can adjust to the odor level. Model CD-1200 will produce
very high levels of ozone at its high setting. Determine the ozone level required by monitoring the exhaust air for odors. Levels
may vary throughout the growing cycle.
No maintenance is required of these units.
Warranty & Repair Policy:
Uvonair CD units are warranted for one year from the time of purchase against any defects in material and manufacturing. It is
warranted only for the application described. Keep your purchase receipt for warranty claim.
· Call the manufacturer at 1 800 765 2098 for the RGA# (Returned Goods Authorization Number) and shipping
instructions.
· Shipments must be prepaid and accompanied with the RGA#.
· Products qualifying for warranty will be repaired at no charge and shipped back prepaid within 24 hours of receipt.
Warning: Recommended for commercial use. Ozone, in concentrations above .05 PPM, may be injurious to health. Ozone has
a half-life of ~ 30 minutes, therefore it will dissipate and not accumulate.

Product Tags

Use spaces to separate tags. Use single quotes (') for phrases.